I-Micomme Non-invasive Ventilator ST-30H
Inkcazo
- I-ventilation engekho-invasive (NIV) isekela ukuphefumla kwesigulane ngaphandle kwesidingo se-intubation okanye i-tracheotomy.I-NIV inikezela ngonyango olusebenzayo kunye nomngcipheko omncinci wosulelo kunye nokuphuculwa kokusinda kwizigulana ezinokusilela kokuphefumla.
- I-Non-invasive ventilation (NIV) kukusetyenziswa kwenkxaso yokuphefumla elawulwa ngemaski yobuso, imaski yeempumlo, okanye i-helmet.Umoya, ngokuqhelekileyo kunye neoksijini eyongezelelweyo, unikezelwa nge-mask phantsi koxinzelelo oluhle;ngokubanzi umthamo woxinzelelo uyatshintshwa ngokuxhomekeke ekubeni umntu uyaphefumla ngaphakathi okanye ngaphandle.
Isicelo
- Izifo ezingapheliyo ze-Pulmonary Obstruction : Ukusetyenziswa kwe-ventilation engekho-invasive (NIV) ukuxhasa izigulane ngexesha lokungaphumeleli kokuphefumla okungapheliyo okwesibini ukuya kwinqanaba lokunyuka kwesifo esingapheliyo sesifo se-pulmonary sinobungqina obungathandabuzekiyo benzuzo malunga nokunciphisa imfuno yokungena, ubude besibhedlele. ukuhlala kunye nokufa.
- I-Acute Respiratory Distress Syndrome (i-ARDS) ibonakala ngokusilela kokuphefumla ngokukrakra, ukusasazeka kwe-pulmonary opacities kunye ne-hypoxemia enzima.Ukusetyenziswa kwe-NIV kunokunceda ukunqanda iingxaki ezinje ngeziganeko eziphezulu ze-pneumonia ehambelana ne-ventilator kunye ne-barotrauma.
Inzuzo
Ubuninzi bokuhamba: 210L / min
Ubuninzi boxinzelelo olukhuthazayo: 30cm H2O
Ukusebenza kwembuyekezo yokuvuza, isixhobo sinikezela nge-90L / min imbuyekezo enkulu yokuvuza, inokuphinda ifezekise uxinzelelo olujoliswe kuyo kwangaphambili ukwenza iqonga loxinzelelo ukugqiba i-trigger echanekileyo kunye nokutshintsha.
I-6-level (100 ~ 600ms) ixesha lokunyusa uxinzelelo, ukuhlangabezana neemfuno ze-physiological of flow flows ezahlukeneyo ekuqaleni kokuphefumlelwa.
Inkcazo
Ipharamitha | ST-30H |
Imo yokungenisa umoya | S/T, CPAP, S, T, PC, VAT |
Ugxininiso lweoksijini | 21% ~ 100%, (ukwanda nge-1%) |
Ubungakanani bekhusi | 5.7 Intshi yesikrini sombala |
Umboniso wamaza | Uxinzelelo / ukuhamba |
IPAP | 4 ~ 30cm H2O |
I-EPAP | 4 ~ 25cm H2O |
I-CPAP | 4 ~ 20cm H2O |
Umthamo wamaza ekujoliswe kuwo | 20-2500mL |
Backup BPM | 1 ~ 60BPM |
Ixesha logcino | 0.2~4.0S |
Ixesha lokunyuka | 1 ~ 6 inqanaba |
Ixesha le-ramp | 0 ~ 60min |
Uxinzelelo lwerampu | Imodi ye-CPAP: 4 ~ 20cm H2O Enye indlela: 4 ~ 25cm H2O |
Ukunciphisa uxinzelelo | 1 ~ 3 inqanaba |
I-Timin ezenzekelayo | 0.2~4.0S |
I-Timax ezenzekelayo | 0.2~4.0S |
I-Trigger setting | Okuzenzekelayo, 1 ~ 3 inqanaba |
Useto lwe-E-Trigger | Okuzenzekelayo, 1 ~ 3 inqanaba |
Qalisa isitshixo | Cima, 0.3~1.5S |
Ukuhamba kwemowudi yeHFNC | N / A |
Ukuhamba okuphezulu | 210L/min |
Ubuninzi bembuyekezo yokuvuza | 90L/min |
Indlela yokulinganisa uxinzelelo | Ityhubhu yokuvavanya uxinzelelo ikwicala lemaski |
Iialamu | I-Apnea|Uqhawulo|Umthamo womzuzu ophantsi|Ivolumu yomsindo ophantsi|Ukucinywa koxinzelelo|noxinzelelo oluphezulu|ioksijini ayifumaneki|Ubonelelo loxinzelelo lweoksijini olugqithileyo|Uxinzelelo loxinzelelo lweoksijini ephantsi|Kucinywe ityhubhu|Ukungasebenzi kweturbine|Ukusilela kwesivamvo seoksijini|Ukusilela kwesivamvo sokuhamba komoya|Uxinzelelo oluphantsi |Ibhetri ephantsi|Ibhetri iphelile |
Apnea alarm range setting | 0S, 10S, 20S, 30S |
Ukuqhawulwa koluhlu lwe-alam yokuseta | 0S, 15S, 60S |
Idatha yokubeka iliso ngexesha langempela | Uxinzelelo lwangoku lweoksijini|Uxinzelelo lomthombo weoksijini|Uxinzelelo|Ukungenisa umoya ngomzuzu ngamnye|Inqanaba lokuphefumla|Ukuvuza okukhoyo|Umthamo wangoku|Indlela yokuqalisa |
Ezinye iisetingi | Ukutshixa isikrini|bonisa ukukhanya|Ukuqukuqela|Uxinzelelo|Ukuma kwamaza |
Gcina ibhetri | Iiyure ezisi-8 |